POSITION OF JUGULAR OXYGEN-SATURATION CATHETER IN PATIENTS WITH HEAD TRAUMA - ASSESSMENT BY USE OF PLAIN FILMS AMERICAN JOURNAL OF ROENTGENOLOGY Bankier, A. A., Fleischmann, D., Windisch, A., Germann, P., PETRITSCHEK, W., WIESMAYR, M. N., Hubsch, P. 1995; 164 (2): 437-441

Abstract

The purpose of this study was to establish a plain radiographic technique for the assessment of the position of a jugular oxygen saturation catheter in patients with head trauma.In the experimental study, jugular oxygen saturation catheters were introduced into the internal jugular veins of four cadavers. Correct positioning of the catheter tips was monitored by CT. Concurrent anteroposterior radiographs of the skulls were obtained with the tubes angled in a transverse plane and in a sagittal plane at intervals of 5 degrees and within a total range of 70 degrees for each plane. Three radiologists judged the visibility of the catheter tips and measured the distance of the catheter tips to previously determined bony landmarks of the skull. Then, preliminary radiologic criteria for correct positioning of the catheters were defined. In the clinical study, we prospectively evaluated radiographs for 32 patients who received jugular oxygen saturation catheters. Eleven patients had digital radiographs done, and 21 patients had radiographs with a conventional screen film system done. Radiographs were analyzed for consistency of findings with the experimental results and for consistency of the suspected catheter position with laboratory data.Results of the cadaveric study showed that catheter position is best assessed on strict anteroposterior radiographs with the orbitomeatal-basal line perpendicular to the plane of the film. A correctly positioned catheter tip should lie cranial to a line extending from the atlantooccipital joint space and caudal to the lower margin of the orbit. The catheter tip also should lie cranial to a line connecting the tips of the mastoid processes, with a catheter tip-to-line distance averaging 20% of the overall distance between the tips of the mastoid processes. According to these criteria, the catheter was properly positioned in 26 of 32 patients. In three patients, the catheter obviously was improperly positioned. Catheter position was equivocal in three other patients; in two of these patients, the catheter was looped within the internal jugular vein. Whereas for all 26 patients with properly positioned catheters values for jugular venous oxygen saturation were congruent with other laboratory data, incongruent saturation values were recorded for five of the six patients with equivocally or obviously improperly positioned catheters.Accurate assessment of the position of a jugular oxygen saturation catheter can be made by use of specific bony landmarks seen on anteroposterior radiographs of the skull.

View details for Web of Science ID A1995QC79400033

View details for PubMedID 7839985