Automated generation of curved planar reformations from volume data: Method and evaluation RADIOLOGY Raman, R., Napel, S., Beaulieu, C. F., Bain, E. S., Jeffrey, R. B., Rubin, G. D. 2002; 223 (1): 275-280

Abstract

The authors developed and evaluated a method to automatically create interactive vascular curved planar reformations with computed tomographic (CT) angiographic data. The method decreased user interaction time by 86%, from 15 to 2 minutes. Expert reviewers were asked to indicate their confidence in differentiating automatically created images from clinical-quality manually produced images. The area under the receiver operating characteristic curve was 0.45 (95% CI: 0.39, 0.51), and a test of equivalency indicated that reviewers could not distinguish between images. They also graded image quality as equivalent to that with manual methods and found fewer artifacts on automatically created images. Automatic methods rapidly produce curved planar reformations of equivalent quality with reduced time and effort.

View details for Web of Science ID 000174611900037

View details for PubMedID 11930078