EFFECT OF RADIOTHERAPY TECHNIQUES (IMRT VS. 3D-CRT) ON OUTCOME IN PATIENTS WITH INTERMEDIATE-RISK RHABDOMYOSARCOMA ENROLLED IN COG D9803-A REPORT FROM THE CHILDREN'S ONCOLOGY GROUP INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS Lin, C., Donaldson, S. S., Meza, J. L., Anderson, J. R., Lyden, E. R., Brown, C. K., Morano, K., Laurie, F., Arndt, C. A., Enke, C. A., Breneman, J. C. 2012; 82 (5): 1764-1770

Abstract

To compare the dosimetric parameters of intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) in patients with intermediate-risk rhabdomyosarcoma and to analyze their effect on locoregional control and failure-free survival (FFS).The study population consisted of 375 patients enrolled in the Children's Oncology Group protocol D9803 study, receiving IMRT or 3D-CRT. Dosimetric data were collected from 179 patients with an available composite plan. The chi-square test or Fisher's exact test was used to compare the patient characteristics and radiotherapy parameters between the two groups. The interval-to-event outcomes were estimated using the Kaplan-Meier method and compared using log-rank tests. Cox proportional hazards regression analysis was used to examine the effect of the treatment technique on FFS after adjusting for primary site and risk group.The median follow-up time was 5.7 and 4.2 years for patients receiving 3D-CRT and IMRT, respectively. No differences in the 5-year failure of locoregional control (18% vs. 15%) or FFS (72% vs. 76%) rates were noted between the two groups. Multivariate analysis revealed no association between the two techniques and FFS. Patients with primary tumors in parameningeal sites were more likely to receive IMRT than 3D-CRT. IMRT became more common during the later years of the study. Patients receiving IMRT were more likely to receive >50 Gy, photon energy of =6 MV, and >5 radiation fields than those who received 3D-CRT. The coverage of the IMRT planning target volume by the prescription dose was improved compared with the coverage using 3D-CRT with similar target dose heterogeneity.IMRT improved the target dose coverage compared with 3D-CRT, although an improvement in locoregional control or FFS could not be demonstrated in this population. Future studies comparing the integral dose to nontarget tissue and late radiation toxicity between the two groups are warranted.

View details for DOI 10.1016/j.ijrobp.2011.01.036

View details for Web of Science ID 000301891300045

View details for PubMedID 21470795

View details for PubMedCentralID PMC3154985