New to MyHealth?
Manage Your Care From Anywhere.
Access your health information from any device with MyHealth. You can message your clinic, view lab results, schedule an appointment, and pay your bill.
ALREADY HAVE AN ACCESS CODE?
DON'T HAVE AN ACCESS CODE?
NEED MORE DETAILS?
MyHealth for Mobile
Effects of Cinacalcet on Fracture Events in Patients Receiving Hemodialysis: The EVOLVE Trial.
Effects of Cinacalcet on Fracture Events in Patients Receiving Hemodialysis: The EVOLVE Trial. Journal of the American Society of Nephrology Moe, S. M., Abdalla, S., Chertow, G. M., Parfrey, P. S., Block, G. A., Correa-Rotter, R., Floege, J., Herzog, C. A., London, G. M., Mahaffey, K. W., Wheeler, D. C., Dehmel, B., Goodman, W. G., Drüeke, T. B. 2015; 26 (6): 1466-1475Abstract
Fractures are frequent in patients receiving hemodialysis. We tested the hypothesis that cinacalcet would reduce the rate of clinical fractures in patients receiving hemodialysis using data from the Evaluation of Cinacalcet HCl Therapy to Lower Cardiovascular Events trial, a placebo-controlled trial that randomized 3883 hemodialysis patients with secondary hyperparathyroidism to receive cinacalcet or placebo for =64 months. This study was a prespecified secondary analysis of the trial whose primary end point was all-cause mortality and non-fatal cardiovascular events, and one of the secondary end points was first clinical fracture event. Clinical fractures were observed in 255 of 1935 (13.2%) patients randomized to placebo and 238 of 1948 (12.2%) patients randomized to cinacalcet. In an unadjusted intention-to-treat analysis, the relative hazard for fracture (cinacalcet versus placebo) was 0.89 (95% confidence interval [95% CI], 0.75 to 1.07). After adjustment for baseline characteristics and multiple fractures, the relative hazard was 0.83 (95% CI, 0.72 to 0.98). Using a prespecified lag-censoring analysis (a measure of actual drug exposure), the relative hazard for fracture was 0.72 (95% CI, 0.58 to 0.90). When participants were censored at the time of cointerventions (parathyroidectomy, transplant, or provision of commercial cinacalcet), the relative hazard was 0.71 (95% CI, 0.58 to 0.87). Fracture rates were higher in older compared with younger patients and the effect of cinacalcet appeared more pronounced in older patients. In conclusion, using an unadjusted intention-to-treat analysis, cinacalcet did not reduce the rate of clinical fracture. However, when accounting for differences in baseline characteristics, multiple fractures, and/or events prompting discontinuation of study drug, cinacalcet reduced the rate of clinical fracture by 16%-29%.
View details for DOI 10.1681/ASN.2014040414
View details for PubMedID 25505257
View details for PubMedCentralID PMC4446874