0060 Particle size distribution in aluminium manufacturing facilities. Occupational and environmental medicine Liu, S., Noth, E. M., Dixon-Ernst, C., Eisen, E. A., Cullen, M. R., Hammond, S. K. 2014; 71: A6-?

Abstract

As part of exposure assessment for an ongoing epidemiologic study of heart disease and fine particle exposures in aluminium manufacturing, area particle samples were collected in smelters and fabrication facilities to assess instrument reliability and particle size distribution at different process areas.Personal Modular Impactors (PMI) and Minimicro-orifice uniform deposition impactors (MiniMOUDI) were used to collect samples. The coefficient of variation (CV) of collocated samples of the same type was used to evaluate the reproducibility of the impactors. PM2.5 measured by PMI was compared to PM2.5 calculated from MiniMOUDI data to assess the validity of using PMI to measure fine particles in personal sampling. Mass median aerodynamic diameter (MMAD) was calculated to characterise particle size distribution at different locations.62 MiniMOUDI and 71 PMI samples were collected at 44 production areas. Most of CVs were less than 30%. The slope of the liner regression of PMI_PM2.5 versus MiniMOUDI_PM2.5 was 1.12 mg/m(3) per mg/m(3) (± 0.05), with correlation coefficient of 0.97 (± 0.01). MMADs in fabrications were significantly smaller and less variable than those in smelters (p = 0.001). The fraction of PM10 which was PM1.0 or PM0.56 was significantly higher in fabrications than in smelters (p < 0.001).The reproducibility for impactors was moderate to high. PM2.5 measured by PMI can be a valid measure for fine particle exposure in personal sampling. The concentrations of submicron and quasi-ultrafine particles were similar in fabrications and smelters. PM2.5 is not a good surrogate for ultrafine particles in this setting.

View details for DOI 10.1136/oemed-2014-102362.18

View details for PubMedID 25018415