Lung Volume Reduction After Stereotactic Ablative Radiation Therapy of Lung Tumors: Potential Application to Emphysema INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS Binkley, M. S., Shrager, J. B., Leung, A. N., Popat, R., Trakul, N., Atwood, T. F., Chaudhuri, A., Maxim, P. G., Diehn, M., Loo, B. W. 2014; 90 (1): 216-223

Abstract

Lung volume reduction surgery (LVRS) improves dyspnea and other outcomes in selected patients with severe emphysema, but many have excessive surgical risk for LVRS. We analyzed the dose-volume relationship for lobar volume reduction after stereotactic ablative radiation therapy (SABR) of lung tumors, hypothesizing that SABR could achieve therapeutic volume reduction if applied in emphysema.We retrospectively identified patients treated from 2007 to 2011 who had SABR for 1 lung tumor, pre-SABR pulmonary function testing, and =6 months computed tomographic (CT) imaging follow-up. We contoured the treated lobe and untreated adjacent lobe(s) on CT before and after SABR and calculated their volume changes relative to the contoured total (bilateral) lung volume (TLV). We correlated lobar volume reduction with the volume receiving high biologically effective doses (BED, a/ß = 3).27 patients met the inclusion criteria, with a median CT follow-up time of 14 months. There was no grade =3 toxicity. The median volume reduction of the treated lobe was 4.4% of TLV (range, -0.4%-10.8%); the median expansion of the untreated adjacent lobe was 2.6% of TLV (range, -3.9%-11.6%). The volume reduction of the treated lobe was positively correlated with the volume receiving BED =60 Gy (r(2)=0.45, P=.0001). This persisted in subgroups determined by high versus low pre-SABR forced expiratory volume in 1 second, treated lobe CT emphysema score, number of fractions, follow-up CT time, central versus peripheral location, and upper versus lower lobe location, with no significant differences in effect size between subgroups. Volume expansion of the untreated adjacent lobe(s) was positively correlated with volume reduction of the treated lobe (r(2)=0.47, P<.0001).We identified a dose-volume response for treated lobe volume reduction and adjacent lobe compensatory expansion after lung tumor SABR, consistent across multiple clinical parameters. These data serve to inform our ongoing prospective trial of stereotactic ablative volume reduction (SAVR) for severe emphysema in poor candidates for LVRS.

View details for DOI 10.1016/j.ijrobp.2014.05.025

View details for Web of Science ID 000341456500029