New to MyHealth?
Manage Your Care From Anywhere.
Access your health information from any device with MyHealth. You can message your clinic, view lab results, schedule an appointment, and pay your bill.
ALREADY HAVE AN ACCESS CODE?
DON'T HAVE AN ACCESS CODE?
NEED MORE DETAILS?
MyHealth for Mobile
Validation of a Novel Radiographic Scoring System for Calcinosis Affecting the Hands of Patients With Systemic Sclerosis
Validation of a Novel Radiographic Scoring System for Calcinosis Affecting the Hands of Patients With Systemic Sclerosis ARTHRITIS CARE & RESEARCH Chung, L., Valenzuela, A., Fiorentino, D., Stevens, K., Li, S., Harris, J., Hutchinson, C., Assassi, S., Beretta, L., Lakshminarayanan, S., Rodriguez-Reyna, T. S., Denton, C. P., Taillefer, R. G., Herrick, A. L., Baron, M. 2015; 67 (3): 425-430Abstract
Objective: There are currently no validated outcome measures to assess calcinosis severity in systemic sclerosis (SSc). We sought to develop and validate a novel radiographic scoring system for calcinosis affecting the hands of SSc patients for potential use in future clinical trials. Methods: Following a 1-hour teleconference training session, 12 investigators (8 rheumatologists, 1 dermatologist, 3 radiologists) scored 12 hand radiographs in random order using two scoring systems (termed "simple" and "complex"), and re-scored 2 randomly assigned radiographs after a minimum of 24 hours. Inter-rater and intra-rater reliability were assessed using a weighted kappa coefficient for the simple system, and intraclass correlation coefficient (ICC) for the complex system (ICC < 0.4 poor, 0.4-0.7 moderate, > 0.7 excellent). Results: Mean time to complete the complex scoring system was significantly longer than the simple scoring system (4.0 vs. 0.4 minutes, p<.0001). Overall inter-rater reliability for the simple scoring system was poor (kappa=0.39, 95% CI 0.1-0.52), but improved if dichotomized as mild/moderate vs. severe (kappa=0.51, 95% CI 0.26-0.7). Inter-rater reliability was excellent for the complex scoring system (ICC=0.89, 95% CI 0.86-0.92). Intra-rater reliability was moderate for the simple scoring system (kappa=0.67, 95% CI 0.37-0.96), but almost perfect for the complex scoring system (ICC=0.93, 95%CI 0.89-0.97). Conclusion: We developed a novel radiographic scoring system that accounts for the area coverage, density, and anatomic location of calcinosis affecting the hands in patients with SSc. This scoring system is feasible with excellent reliability and should undergo further validation testing for use in clinical trials. © 2014 American College of Rheumatology.
View details for DOI 10.1002/acr.22434
View details for PubMedID 25155948