Trajectory Modulated Arc Therapy: A Fully Dynamic Delivery With Synchronized Couch and Gantry Motion Significantly Improves Dosimetric Indices Correlated With Poor Cosmesis in Accelerated Partial Breast Irradiation INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS Liang, J., Atwood, T., von Eyben, R., Fahimian, B., Chin, E., Horst, K., Otto, K., Hristov, D. 2015; 92 (5): 1148-1156

Abstract

To develop planning and delivery capabilities for linear accelerator-based nonisocentric trajectory modulated arc therapy (TMAT) and to evaluate the benefit of TMAT for accelerated partial breast irradiation (APBI) with the patient in prone position.An optimization algorithm for volumetrically modulated arc therapy (VMAT) was generalized to allow for user-defined nonisocentric TMAT trajectories combining couch rotations and translations. After optimization, XML scripts were automatically generated to program and subsequently deliver the TMAT plans. For 10 breast patients in the prone position, TMAT and 6-field noncoplanar intensity modulated radiation therapy (IMRT) plans were generated under equivalent objectives and constraints. These plans were compared with regard to whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose.For TMAT APBI, nonisocentric collision-free horizontal arcs with large angular span (251.5 ± 7.9°) were optimized and delivered with delivery time of ~4.5 minutes. Percentage changes of whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose for TMAT relative to IMRT were -10.81% ± 6.91%, -27.81% ± 7.39%, -14.82% ± 9.67%, and 39.40% ± 10.53% (P=.01).This is a first demonstration of end-to-end planning and delivery implementation of a fully dynamic APBI TMAT. Compared with IMRT, TMAT resulted in marked reduction of the breast tissue volume irradiated at high doses.

View details for DOI 10.1016/j.ijrobp.2015.04.034

View details for Web of Science ID 000357900600037

View details for PubMedID 26050608