Anesthesia for Placement of a Paracorporeal Lung Assist Device and Subsequent Heart-Lung Transplantation in a Child with Suprasystemic Pulmonary Hypertension and End-Stage Respiratory Failure. A & A case reports Char, D. S., Yarlagadda, V., Maeda, K., Williams, G. 2016; 6 (10): 308-310

Abstract

Pediatric patients with end-stage respiratory failure and pulmonary hypertension traditionally have poor outcomes when bridged with extracorporeal membrane oxygenation to lung or heart-lung transplantation. Therefore, several institutions have attempted paracorporeal lung assist devices as a bridge. However, given the small number of patients, little is known about approaches to anesthetic induction in these hemodynamically unstable patients either before placement of a device or anesthetic induction once a device is in situ. In this case report, we describe our anesthetic experience managing a 13-year-old boy for both paracorporeal lung assist device placement and subsequent heart-lung transplantation.

View details for DOI 10.1213/XAA.0000000000000300