Time-resolved three-dimensional imaging of the left atrium and pulmonary veins in the interventional suite - A comparison between muttisweep gated rotational three-dimensional reconstructed fluoroscopy and multislice computed tomography
Time-resolved three-dimensional imaging of the left atrium and pulmonary veins in the interventional suite - A comparison between muttisweep gated rotational three-dimensional reconstructed fluoroscopy and multislice computed tomography HEART RHYTHM Al-Ahmad, A., Wigstroem, L., Sandner-Porkristl, D., Wang, P. J., Zei, P. C., Boese, J., Lauritsch, G., Moore, T., Chan, F., Fahrig, R. 2008; 5 (4): 513-519Abstract
Cardiac computed tomography (CT) is commonly used to visualize left atrial (LA) anatomy for ablation of atrial fibrillation. We have developed a new imaging technique that allows acquisition and visualization of three-dimensional (3D) cardiac images in the catheter lab.We sought to compare LA and pulmonary vein (PV) dimensions acquired using gated multisweep rotational fluoroscopy (C-arm CT) system and multislice computed tomography (MSCT) in an in vivo porcine model.A Siemens AXIOM Artis dTA C-arm system (Siemens AG, Medical Solutions) was modified to allow acquisition of four bidirectional sweeps during synchronized acquisition of the electrocardiogram signal to allow retrospective gating. C-arm CT image volumes were then reconstructed. Gated MSCT (SOMATOM Sensation 16 and 64, Siemens AG, Medical Solutions) and C-arm CT images were acquired in six animals. The two main PV diameters were measured in orthogonal axes. LA volumes were calculated. C-arm CT measurements were compared with the MSCT measurements.The average PV diameters using the C-arm CT were 2.24 x 1.35 cm, versus 2.27 x 1.38 cm for CT. The average difference was 0.034 cm (1.9%) between the C-arm CT and standard CT. The average LA volume using MSCT was 49.1 +/- 12.7 cm(3), as compared with 51.0 +/- 8.7 cm(3) obtained by the C-arm CT. The average difference between the C-arm CT and the MSCT was 1.9 cm(3) (3.7%). There were no significant differences in either the PV or LA measurements.Visualization of 3D cardiac anatomy during ablation procedures is possible and highly accurate. The 3D cardiac reconstructions acquired during ablation procedures will be valuable for procedural planning and guidance.
View details for DOI 10.1016/j.hrthm.2007.12.027
View details for Web of Science ID 000254596600003
View details for PubMedID 18362018