New to MyHealth?
Manage Your Care From Anywhere.
Access your health information from any device with MyHealth. You can message your clinic, view lab results, schedule an appointment, and pay your bill.
ALREADY HAVE AN ACCESS CODE?
DON'T HAVE AN ACCESS CODE?
NEED MORE DETAILS?
MyHealth for Mobile
Comparison of T2*GRE and DSC-PWI for hemorrhage detection in acute ischemic stroke patients: Pooled analysis of the EPITHET, DEFUSE 2, and SENSE 3 stroke studies.
Comparison of T2*GRE and DSC-PWI for hemorrhage detection in acute ischemic stroke patients: Pooled analysis of the EPITHET, DEFUSE 2, and SENSE 3 stroke studies. International journal of stroke : official journal of the International Stroke Society Amukotuwa, S. A., Fischbein, N. J., Albers, G. W., Davis, S. n., Donnan, G. A., Andre, J. B., Bammer, R. n. 2019: 1747493019858781Abstract
The objective of this study was to compare the diagnostic performance of the baseline pre-contrast images of dynamic susceptibility contrast perfusion-weighted imaging (DSC-PWI) with conventional T2*gradient recalled echo (GRE) imaging for detection of hemorrhage in acute ischemic stroke patients.T2*GRE and DSC-PWI from 393 magnetic resonance imaging scans from 221 patients enrolled in three prospective stroke studies were independently evaluated by two readers blinded to clinical and other imaging data. Agreement between T2*GRE and DSC-PWI for the presence of hemorrhage, and acute hemorrhagic transformation, was assessed using the kappa statistic. Inter-reader agreement was also assessed using the kappa statistic.Agreement between the baseline images of DSC-PWI and T2*GRE regarding the presence of hemorrhage was almost perfect (kreader?1?:?0.90, 95% confidence interval 0.86-0.95 and kreader?2?:?0.91, 95% confidence interval 0.87-0.96). Agreement between the sequences was still higher for detection of acute hemorrhagic transformation (kreader?1?:?0.94, 95% confidence interval 0.91-0.98 and kreader?2?:?0.95, 95% confidence interval 0.92-0.98). Inter-reader agreement for detection of hemorrhage was also almost perfect for both T2*GRE (k: 0.95, 95% confidence interval 0.91-0.98) and DSC-PWI (k: 0.96, 95% confidence interval 0.93-0.99). Acute hemorrhagic transformation detected on T2*GRE was missed on DSC-PWI by one or both readers in 5/393 (1.3%) scans.The almost perfect statistical agreement between DSC-PWI and conventional T2*GRE suggests that DSC-PWI is sufficient for hemorrhage screening prior to thrombolysis in stroke patients. T2*GRE can therefore be omitted when DSC-PWI is included, thereby shortening the acute ischemic stroke magnetic resonance imaging protocol and expediting treatment. Trial registration: ClinicalTrials.gov Identifier: NCT02586415.
View details for DOI 10.1177/1747493019858781
View details for PubMedID 31291850