Ultra-sensitive Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Antigen Detection for the Diagnosis of Coronavirus Disease 2019 (COVID-19) in Upper Respiratory Samples. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America Wang, H., Hogan, C. A., Verghese, M., Solis, D., Sibai, M., Huang, C., Zehnder, J., Sahoo, M. K., Pinsky, B. A. 2021

Abstract

An ultra-sensitive severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleocapsid antigen assay (S-PLEX, MesoScale Diagnostics) was evaluated in 250 retrospective and 200 prospective upper respiratory specimens. In samples with cycle threshold <35, there was 95%-98% positive and 93%-96% negative percent agreement with reverse transcription-polymerase chain reaction. S-PLEX may provide a high-throughput alternative to nucleic acid-based testing for coronavirus disease 2019 (COVID-19) diagnosis.

View details for DOI 10.1093/cid/ciab063

View details for PubMedID 33830203