New to MyHealth?
Manage Your Care From Anywhere.
Access your health information from any device with MyHealth. You can message your clinic, view lab results, schedule an appointment, and pay your bill.
ALREADY HAVE AN ACCESS CODE?
DON'T HAVE AN ACCESS CODE?
NEED MORE DETAILS?
MyHealth for Mobile
Get the iPhone MyHealth app »
Get the Android MyHealth app »
Abstract
To evaluate the time-effectiveness, inter-observer variance, and accuracy of left ventricular ejection fraction (EF) measurements using retrospectively ECG-gated four-channel multi-detector row CT (MDCT) angiography in comparison with biplane cine-ventriculography.Twenty consecutive patients underwent retrospectively ECG-gated MDCT angiography and conventional coronary angiography with biplane ventriculography. Raw MDCT data were reconstructed at 0 % - 90 % of the cardiac cycle in increments of 10 %. Ten geometrically identical multiplanar reformations parallel to the short axis of the heart were reconstructed in each patient. Three blinded readers segmented the left ventricle in the end-systolic and end-diastolic phase using standardized window settings in order to determine the EF. The EF was measured with biplane cine-ventriculography by two blinded readers and was compared with MDCT. The time needed for post-processing was recorded and the inter-observer agreement for both imaging techniques was assessed.Mean post-processing time was 63 +/- 3 min per patient for MDCT and 5.5 +/- 1.2 min for ventriculography. MDCT and ventriculography showed a good correlation (r = 0.83, p < 0.0001) for measurement of the EF. Mean errors of EF measurements for the three MDCT readers compared with the mean of the ventriculography were - 6.3 +/- 6.6 %, - 4.7 +/- 7.1 % and - 4.6 +/- 5.7 %, respectively. The mean differences between the three readers assessing MDCT were - 1.6 +/- 3.2 % (reader 1 versus 2, r = 0.96), - 1.6 +/- 5.6 % (1 versus 3, r = 0.95) and - 0.011 +/- 2.9 % (2 versus 3, r = 0.97, p < 0.0001). The mean differences between the two readers assessing ventriculography was 0.32 +/- 5.1 % (r = 0.88, p < 0.0001).MDCT correlates well with biplane cine-ventriculography but has the tendency to underestimate the left ventricular EF. Measurements using MDCT have a high inter-observer agreement, however, the time needed for additional MDCT data post-processing is still unacceptably long.
View details for DOI 10.1055/s-2004-813012
View details for Web of Science ID 000221116000009
View details for PubMedID 15088177