The medtronic MiniMed gold continuous glucose monitoring system: An effective means to discover hypo- and Hyperglycemia in children under 7 years of age DIABETES TECHNOLOGY & THERAPEUTICS Gandrud, L. M., Xing, D., Kollman, C., Block, J. M., Kunselman, B., Wilson, D. M., Buckingham, B. A. 2007; 9 (4): 307-316

Abstract

The glycemic patterns of children less than 7 years with type 1 diabetes have not been well studied using continuous glucose monitoring. Our goal was to assess the incidence of hypoglycemia as well as postprandial glycemic patterns in this age group utilizing continuous glucose monitoring.Nineteen children used the Medtronic MiniMed (Northridge, CA) CGMS System Gold on three to seven occasions over approximately 6 months.Nineteen children (nine girls and 10 boys; mean age 4.8 +/- 1.4 years, range 1.6-6.8 years) used the CGMS 102 times, providing 434 days of data; 79% of days were optimal based on CGMS Solutions software version 3.0. Mild hypoglycemia (glucose or=2 mg/dL/min following 50% of breakfasts. Children with hemoglobin A1c levels >or=8% had higher postprandial glucose concentrations. There was no significant advantage of continuous subcutaneous insulin infusion therapy over multiple daily injection therapy in decreasing postprandial hyperglycemia.CGMS tracings from young children with diabetes demonstrate frequent mild nocturnal hypoglycemia and significant postprandial hyperglycemia, with a rapid rise in glucose following the meal. The most rapid rate of rise and the most severe postprandial hyperglycemia occurred after breakfast.

View details for DOI 10.1089/dia.2007.0026