Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report. A&A practice Lui, N. S., Guo, H. H., Sung, A. W., Peterson, A., Kulkarni, V. N. 2019

Abstract

We present a case of a 69-year-old man who underwent tracheobronchoplasty for tracheobronchomalacia using a single-lumen endotracheal tube and a Y-shaped bronchial blocker for airway management. Tracheobronchoplasty is performed by sewing mesh to plicate the posterior, membranous wall of the distal trachea and main bronchi through a right posterolateral thoracotomy. The goals of airway management include continuous left-lung ventilation and lung protection from aspiration. Ideally, only conventional airway management tools are used. This case demonstrates that a single-lumen endotracheal tube with a bronchial blocker can be a straightforward strategy for airway management during tracheobronchoplasty.

View details for DOI 10.1213/XAA.0000000000001076

View details for PubMedID 31385817